Zero-field NMR with an abrupt field drop.
+
Zero-field NMR experiment with an abrupt field drop that propagates the initial condition through an exponential drop in the external magnetic field and then detects at zero field.
  
 
==Syntax==
 
==Syntax==
Line 6: Line 6:
 
     fid=zulf_abrupt(spin_system,parameters,H,R,K)
 
     fid=zulf_abrupt(spin_system,parameters,H,R,K)
  
==Description==
+
==Parameters==
Zero-field magnetometry experiment that propagates the initial condition through an exponential drop in the external magnetic field and then runs the detection at zero field.
 
 
 
==Arguments==
 
  
 
     parameters.drop_field  - the magnetic field that the sample should  
 
     parameters.drop_field  - the magnetic field that the sample should  
Line 18: Line 15:
 
   
 
   
 
     parameters.drop_npoints - number of discretisation points in the drop
 
     parameters.drop_npoints - number of discretisation points in the drop
 
+
 
     parameters.drop_rate    - field drop rate, Hz
 
     parameters.drop_rate    - field drop rate, Hz
 
   
 
   
Line 45: Line 42:
  
 
==See also==
 
==See also==
[[zerofield.m]], [[fieldscan_enlev.m]], [[fieldscan_magn.m]]
+
[[zerofield.m]], [[fieldscan_enlev.m]], [[fieldscan_magn.m]], [[rydmr.m]], [[Built-in_experiments]]
  
 
''Version 2.1, authors: [[Ilya Kuprov]]''
 
''Version 2.1, authors: [[Ilya Kuprov]]''

Latest revision as of 19:43, 6 June 2026

Zero-field NMR experiment with an abrupt field drop that propagates the initial condition through an exponential drop in the external magnetic field and then detects at zero field.

Syntax

    fid=zulf_abrupt(spin_system,parameters,H,R,K)

Parameters

   parameters.drop_field   - the magnetic field that the sample should 
                             be dropped to, starting from the field spe-
                             cified in sys.magnet, Tesla

   parameters.drop_time    - drop time, seconds

   parameters.drop_npoints - number of discretisation points in the drop

   parameters.drop_rate    - field drop rate, Hz

   parameters.sweep        - sweep width during acquisition

   parameters.npoints      - number of points during acquisition

   parameters.detection    - 'uniaxial' to emulate common ZULF
                             hardware, 'quadrature' for proper
                             frequency sign discrimination

   parameters.flip_angle   - pulse flip angle in radians for
                             protons; for other nuclei, this
                             will be scaled by the gamma ratio

Outputs

     fid          - the free induction decay detected on the
                   internally generated gamma-weighted state

Notes

This function ignores the offset parameter and makes its own Hamiltonian.

Examples

See zero_field_acetonitrile.m file in examples/nmr_zerofield directory.

See also

zerofield.m, fieldscan_enlev.m, fieldscan_magn.m, rydmr.m, Built-in_experiments

Version 2.1, authors: Ilya Kuprov