Difference between revisions of "Basic 1d hard.m"
(Created page with "{{DISPLAYTITLE:function.m}} Basic 1D imaging sequence with a hard pulse. ==Syntax== fid=basic_1d_hard(spin_system,parameters,H,R,K,G,F) ==Description== This sequence m...") |
(Sync syntax/arguments/outputs with current Spinach source) |
||
| Line 1: | Line 1: | ||
| − | {{DISPLAYTITLE: | + | {{DISPLAYTITLE:basic_1d_hard.m}} __NOTOC__ |
| + | |||
Basic 1D imaging sequence with a hard pulse. | Basic 1D imaging sequence with a hard pulse. | ||
==Syntax== | ==Syntax== | ||
| − | + | fid=basic_1d_hard(spin_system,parameters,H,R,K,G,F) | |
| − | == | + | ==Arguments== |
| − | |||
| − | + | parameters.ro_grad_amp - readout gradient amplitude, T/m | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
parameters.sweep - detection sweep width, Hz | parameters.sweep - detection sweep width, Hz | ||
| − | + | ||
parameters.npoints - number of points in the fid | parameters.npoints - number of points in the fid | ||
| − | + | ||
parameters.offset - transmitter and receiver offset, Hz | parameters.offset - transmitter and receiver offset, Hz | ||
==Outputs== | ==Outputs== | ||
| − | + | fid - free induction decay that should be Fourier transformed | |
to obtain the image | to obtain the image | ||
==Examples== | ==Examples== | ||
| + | |||
See gradient_image_1d.m file in examples/imaging directory. | See gradient_image_1d.m file in examples/imaging directory. | ||
==See also== | ==See also== | ||
| + | |||
[[phase_enc.m]], [[dwi.m]], [[epi.m]] | [[phase_enc.m]], [[dwi.m]], [[epi.m]] | ||
''Version 2.1, authors: [[Ilya Kuprov]], [[Ahmed Allami]]'' | ''Version 2.1, authors: [[Ilya Kuprov]], [[Ahmed Allami]]'' | ||
| + | |||
| + | ==Description== | ||
| + | |||
| + | This sequence must be called from the [[imaging.m]] context, which would provide H,R,K,G, and F. | ||
Revision as of 15:12, 5 April 2026
Basic 1D imaging sequence with a hard pulse.
Syntax
fid=basic_1d_hard(spin_system,parameters,H,R,K,G,F)
Arguments
parameters.ro_grad_amp - readout gradient amplitude, T/m
parameters.sweep - detection sweep width, Hz
parameters.npoints - number of points in the fid
parameters.offset - transmitter and receiver offset, Hz
Outputs
fid - free induction decay that should be Fourier transformed
to obtain the image
Examples
See gradient_image_1d.m file in examples/imaging directory.
See also
Version 2.1, authors: Ilya Kuprov, Ahmed Allami
Description
This sequence must be called from the imaging.m context, which would provide H,R,K,G, and F.