Difference between revisions of "Dnp field scan.m"
(→See also) |
|||
| Line 1: | Line 1: | ||
| − | Magnetic field scan steady-state DNP experiment. | + | {{DISPLAYTITLE:dnp_field_scan.m}} __NOTOC__ |
| − | + | Magnetic field scan steady-state DNP experiment. Returns the steady-state population of the user-specified state as a function of magnetic field. | |
| − | |||
| − | Returns the steady-state population of the user-specified state as a function of magnetic field. | ||
==Syntax== | ==Syntax== | ||
| − | + | dnp=dnp_field_scan(spin_system,parameters,H,R,K) | |
| − | |||
| − | |||
==Arguments== | ==Arguments== | ||
| Line 31: | Line 27: | ||
to use ILU preconditioned GMRES | to use ILU preconditioned GMRES | ||
| − | H | + | H - Hamiltonian matrix, received from context function |
| − | R | + | R - relaxation superoperator, received from context function |
| − | K | + | K - kinetics superoperator, received from context function |
==Returns== | ==Returns== | ||
| − | + | dnp - an array of the steady state amplitudes of the | |
| − | + | states specified in parameters.coil as at each | |
| − | + | of the magnetic fields supplied | |
==Examples== | ==Examples== | ||
| Line 56: | Line 52: | ||
# Thermal equilibrium state is assumed to be the same at all fields in the sweep. Do not use this function for broad magnetic field sweep experiments. | # Thermal equilibrium state is assumed to be the same at all fields in the sweep. Do not use this function for broad magnetic field sweep experiments. | ||
# Backslash method is recommended for small spin systems and GMRES method for large ones. | # Backslash method is recommended for small spin systems and GMRES method for large ones. | ||
| − | |||
==See also== | ==See also== | ||
| Line 62: | Line 57: | ||
| − | '' | + | ''Version 2.5, authors: [[Ilya Kuprov]], [[Walter Kockenberger]], [[Alexander Karabanov]]'' |
Revision as of 14:50, 20 September 2020
Magnetic field scan steady-state DNP experiment. Returns the steady-state population of the user-specified state as a function of magnetic field.
Syntax
dnp=dnp_field_scan(spin_system,parameters,H,R,K)
Arguments
parameters.mw_pwr - microwave power, Hz
parameters.mw_frq - microwave frequency, Hz
parameters.fields - a vector of B0 field values, T
parameters.rho_eq - thermal equilibrium state
parameters.coil - detection state vector or a horizon-
tal stack thereof
parameters.mw_oper - microwave irradiation operator
parameters.ez_oper - Lz operator on the electrons
parameters.method - 'backslash' to use Matlab's
linear equation solver, 'gmres'
to use ILU preconditioned GMRES
H - Hamiltonian matrix, received from context function
R - relaxation superoperator, received from context function
K - kinetics superoperator, received from context function
Returns
dnp - an array of the steady state amplitudes of the
states specified in parameters.coil as at each
of the magnetic fields supplied
Examples
Cross effect in a system with two spin-1/2 electrons (cross_effect_field_scan_1.m example file in examples/dnp_solids directory):
Solid effect in a system with a spin-7/2 gadolinium ion (solid_effect_field_scan_1.m example file in examples/dnp_solids directory):
Notes
- The relaxation superoperator supplied to this function should NOT be thermalized.
- Thermal equilibrium state is assumed to be the same at all fields in the sweep. Do not use this function for broad magnetic field sweep experiments.
- Backslash method is recommended for small spin systems and GMRES method for large ones.
See also
dnp_freq_scan.m, masdnp.m, solid_effect.m
Version 2.5, authors: Ilya Kuprov, Walter Kockenberger, Alexander Karabanov