Difference between revisions of "Cp acquire soft.m"
(→See also) |
(Update function See also links and function index membership) |
||
| (6 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
| − | {{DISPLAYTITLE: | + | {{DISPLAYTITLE:cp_acquire_soft.m}} __NOTOC__ |
| − | Cross-polarisation | + | Cross-polarisation experiment in the rotating frame, followed by time-domain FID acquisition. The CP stage is preceded by wiping of the low-gamma spins and followed by FID acquisition with decoupling of the high-gamma spins. |
==Syntax== | ==Syntax== | ||
| − | fid= | + | fid=cp_acquire_soft(spin_system,parameters,H,R,K) |
| − | == | + | ==Parameters== |
| − | parameters.spins - working | + | parameters.spins - working spins, a cell array of |
| − | strings with high-gamma | + | strings with high-gamma spin fi- |
| − | rst, | + | rst, and low-gamma spin last, |
| + | for example {'1H','13C'} | ||
| − | parameters.hi_pwr - nutation frequency of the | + | parameters.hi_pwr - nutation frequency of the exci- |
| − | + | tation pulse on the high-gamma | |
| − | + | channel, Hz | |
parameters.cp_pwr - nutation frequencies on the two | parameters.cp_pwr - nutation frequencies on the two | ||
| Line 23: | Line 24: | ||
parameters.rho0 - initial state, the state of the | parameters.rho0 - initial state, the state of the | ||
| − | low-gamma | + | low-gamma spins will be wiped |
parameters.coil - detection state | parameters.coil - detection state | ||
| Line 44: | Line 45: | ||
==See also== | ==See also== | ||
| − | [[Built-in_experiments | + | [[cp_contact_soft.m]], [[cp_contact_hard.m]], [[overtone_cp.m]], [[cn2d_dq.m]], [[cn2d_sq.m]], [[dante.m]], [[fslghetcor.m]], [[mqmas.m]], [[nqr_pa.m]], [[pdsd.m]], [[respiration.m]], [[wise.m]], [[Built-in_experiments]] |
| − | [[ | + | ''Version 2.9, authors: [[Marina Carravetta]], [[Phil Williamson]], [[Guinevere Mathies]], [[Ilya Kuprov]]'' |
| − | |||
| − | |||
| − | |||
Latest revision as of 19:35, 6 June 2026
Cross-polarisation experiment in the rotating frame, followed by time-domain FID acquisition. The CP stage is preceded by wiping of the low-gamma spins and followed by FID acquisition with decoupling of the high-gamma spins.
Syntax
fid=cp_acquire_soft(spin_system,parameters,H,R,K)
Parameters
parameters.spins - working spins, a cell array of
strings with high-gamma spin fi-
rst, and low-gamma spin last,
for example {'1H','13C'}
parameters.hi_pwr - nutation frequency of the exci-
tation pulse on the high-gamma
channel, Hz
parameters.cp_pwr - nutation frequencies on the two
channels during the CP contact
time, a two-element vector, Hz
parameters.cp_dur - duration of the contact time, s
parameters.rho0 - initial state, the state of the
low-gamma spins will be wiped
parameters.coil - detection state
H - Hamiltonian matrix, received from context function
R - relaxation superoperator, received from context function
K - kinetics superoperator, received from context function
Outputs
fid - signal detected on the coil state during
system evolution
Examples
Below is the output of examples/nmr_solids/cp_acquire_mas_gly.m example file, showing 1H-13C cross-polarisation followed by acquisition under magic angle spinning in alpha-glycine powder.
See also
cp_contact_soft.m, cp_contact_hard.m, overtone_cp.m, cn2d_dq.m, cn2d_sq.m, dante.m, fslghetcor.m, mqmas.m, nqr_pa.m, pdsd.m, respiration.m, wise.m, Built-in_experiments
Version 2.9, authors: Marina Carravetta, Phil Williamson, Guinevere Mathies, Ilya Kuprov