Difference between revisions of "Dnp field scan.m"
(Restore pre-bulk-edit wiki content) |
(Update function See also links and function index membership) |
||
| (2 intermediate revisions by the same user not shown) | |||
| Line 6: | Line 6: | ||
dnp=dnp_field_scan(spin_system,parameters,H,R,K) | dnp=dnp_field_scan(spin_system,parameters,H,R,K) | ||
| − | == | + | ==Parameters== |
parameters.mw_pwr - microwave power, Hz | parameters.mw_pwr - microwave power, Hz | ||
| Line 59: | Line 59: | ||
==See also== | ==See also== | ||
| − | [[Built-in_experiments | + | [[beamdnp.m]], [[dnp_freq_scan.m]], [[dnp_time_dep.m]], [[masdnp.m]], [[noveldnp.m]], [[noveldnp_steady.m]], [[solid_effect.m]], [[topdnp.m]], [[xixdnp.m]], [[xixdnp_steady.m]], [[Built-in_experiments]] |
| − | |||
''Version 2.5, authors: [[Ilya Kuprov]], [[Walter Kockenberger]], [[Alexander Karabanov]], [[Maria Grazia Concilio]]'' | ''Version 2.5, authors: [[Ilya Kuprov]], [[Walter Kockenberger]], [[Alexander Karabanov]], [[Maria Grazia Concilio]]'' | ||
Latest revision as of 19:36, 6 June 2026
Magnetic field scan steady-state DNP experiment. Returns the steady-state population of the user-specified state as a function of magnetic field.
Syntax
dnp=dnp_field_scan(spin_system,parameters,H,R,K)
Parameters
parameters.mw_pwr - microwave power, Hz
parameters.mw_frq - microwave frequency offset from
the free electron frequency at
the reference B0 field, Hz
parameters.fields - a vector of magnetic field off-
sets from the reference B0 field,
Tesla
parameters.rho0 - equilibrium state at the reference
B0 field
parameters.coil - detection state vector or a horizon-
tal stack thereof
parameters.mw_oper - microwave irradiation operator
parameters.ez_oper - Lz operator on the electrons
parameters.method - 'backslash' to use Matlab's
linear equation solver, 'gmres'
to use ILU preconditioned GMRES
H - Hamiltonian matrix, received from context function
R - relaxation superoperator, received from context function
K - kinetics superoperator, received from context function
Returns
dnp - an array of the steady state amplitudes of the
states specified in parameters.coil as at each
of the magnetic fields supplied
Examples
Cross effect in a system with two spin-1/2 electrons (cross_effect_field_scan_1.m example file in examples/dnp_solids directory):
Solid effect in a system with a spin-7/2 gadolinium ion (solid_effect_field_scan_1.m example file in examples/dnp_solids directory):
Notes
- The relaxation superoperator supplied to this function should NOT be thermalized.
- Thermal equilibrium state is assumed to be the same at all fields in the sweep. Do not use this function for broad magnetic field sweep experiments.
- Backslash method is recommended for small spin systems and GMRES method for large ones.
See also
beamdnp.m, dnp_freq_scan.m, dnp_time_dep.m, masdnp.m, noveldnp.m, noveldnp_steady.m, solid_effect.m, topdnp.m, xixdnp.m, xixdnp_steady.m, Built-in_experiments
Version 2.5, authors: Ilya Kuprov, Walter Kockenberger, Alexander Karabanov, Maria Grazia Concilio