Difference between revisions of "Epi 3d.m"

From Spinach Documentation Wiki
Jump to: navigation, search
(Created page with "{{DISPLAYTITLE:epi_3d.m}} __NOTOC__ Diffusion weighted 3D echo planar imaging pulse sequence. This sequence must be called from the imaging.m context, which would provide...")
 
(Update function See also links and function index membership)
 
(3 intermediate revisions by the same user not shown)
Line 6: Line 6:
 
     fid=epi_3d(spin_system,parameters,H,R,K,G,F)
 
     fid=epi_3d(spin_system,parameters,H,R,K,G,F)
  
==Arguments==
+
==Parameters==
  
 
   parameters.ss_grad_amp  -  the amplitude of slice selection  
 
   parameters.ss_grad_amp  -  the amplitude of slice selection  
Line 18: Line 18:
 
   
 
   
 
   parameters.pe_grad_amp  -  phase encoding gradient amplitude, T/m
 
   parameters.pe_grad_amp  -  phase encoding gradient amplitude, T/m
 
+
 
   parameters.ro_grad_amp  -  readout gradient amplitude, T/m
 
   parameters.ro_grad_amp  -  readout gradient amplitude, T/m
 
   
 
   
Line 34: Line 34:
  
 
==See also==
 
==See also==
[[Imaging module]]
+
[[imaging.m]], [[basic_1d_hard.m]], [[cpmg_dec.m]], [[epi_2d.m]], [[fse.m]], [[grad_echo.m]], [[phase_enc_2d.m]], [[phase_enc_3d.m]], [[press_1d.m]], [[press_2d.m]], [[press_voxel_1d.m]], [[press_voxel_2d.m]], [[press_voxel_3d.m]], [[slice_select_1d.m]], [[spin_echo.m]], [[spiral.m]], [[udd_dec.m]], [[uhrig_times.m]], [[Built-in_experiments]], [[Mri_sequence_list]], [[Imaging module]]
 
 
  
 
''Version 2.9, authors: [[Ilya Kuprov]], [[Ahmed Allami]]''
 
''Version 2.9, authors: [[Ilya Kuprov]], [[Ahmed Allami]]''

Latest revision as of 19:36, 6 June 2026

Diffusion weighted 3D echo planar imaging pulse sequence. This sequence must be called from the imaging.m context, which would provide H,R,K,G, and F.

Syntax

    fid=epi_3d(spin_system,parameters,H,R,K,G,F)

Parameters

 parameters.ss_grad_amp   -  the amplitude of slice selection 
                             gradient,T/m

 parameters.ss_grad_dur   -  the duration of the slice selection 
                             gradient, seconds 

 parameters.image_size    -  number of points in each dimension of
                             the resulting image

 parameters.pe_grad_amp   -  phase encoding gradient amplitude, T/m

 parameters.ro_grad_amp   -  readout gradient amplitude, T/m

 parameters.grad_dur      -  the duration of the gradients, seconds

 parameters.t_echo        -  echo time after slice selection, seconds

 parameters.diff_g_amp    -  [optional] a vector of diffusion gra-
                             dient pair amplitudes in X,Y (T/m) to
                             be active during the echo time

Outputs

    fid - k-space representation of the image 

See also

imaging.m, basic_1d_hard.m, cpmg_dec.m, epi_2d.m, fse.m, grad_echo.m, phase_enc_2d.m, phase_enc_3d.m, press_1d.m, press_2d.m, press_voxel_1d.m, press_voxel_2d.m, press_voxel_3d.m, slice_select_1d.m, spin_echo.m, spiral.m, udd_dec.m, uhrig_times.m, Built-in_experiments, Mri_sequence_list, Imaging module

Version 2.9, authors: Ilya Kuprov, Ahmed Allami