epi_3d.m
Diffusion weighted 3D echo planar imaging pulse sequence. This sequence must be called from the imaging.m context, which would provide H,R,K,G, and F.
Syntax
fid=epi_3d(spin_system,parameters,H,R,K,G,F)
Parameters
parameters.ss_grad_amp - the amplitude of slice selection
gradient,T/m
parameters.ss_grad_dur - the duration of the slice selection
gradient, seconds
parameters.image_size - number of points in each dimension of
the resulting image
parameters.pe_grad_amp - phase encoding gradient amplitude, T/m
parameters.ro_grad_amp - readout gradient amplitude, T/m
parameters.grad_dur - the duration of the gradients, seconds
parameters.t_echo - echo time after slice selection, seconds
parameters.diff_g_amp - [optional] a vector of diffusion gra-
dient pair amplitudes in X,Y (T/m) to
be active during the echo time
Outputs
fid - k-space representation of the image
See also
imaging.m, basic_1d_hard.m, cpmg_dec.m, epi_2d.m, fse.m, grad_echo.m, phase_enc_2d.m, phase_enc_3d.m, press_1d.m, press_2d.m, press_voxel_1d.m, press_voxel_2d.m, press_voxel_3d.m, slice_select_1d.m, spin_echo.m, spiral.m, udd_dec.m, uhrig_times.m, Built-in_experiments, Mri_sequence_list, Imaging module
Version 2.9, authors: Ilya Kuprov, Ahmed Allami